HomeLeak detection systemsZone Controllers (Wi-LD)
Home/Leak detection systems
Zone Controllers (Wi-LD)
Key Features
Wireless with compact ABS enclosure
Couples with up to 50 feet (15.24m) of leak detection sensing cable or a spot detector
Transmission range of up to 100 feet (30.5m)
3.6V lithium AA battery life up to two years
Electronics feature a condensation-resistant coating
Reliable communication
FCC certified transmitter
Pairs with conductive fluid sensing cable, chemical sensing cable, an SD-Z or an SD-Z1 for single zone leak detection
Easy installation and simple to relocate
Power: 3.6V Battery Lithium AA; included
Lithium AA Battery Life: Up to 2 years
Included Accessories: Leader cable and end-of-line terminator (EOL)
Additional Equipment Required for Operation
Wi-MGR
Conductive fluid sensing cable, chemical sensing cable, an SD-Z or an SD-Z1
Leader cable and end-of-line terminator (included – required only for SD-Z and sensing cable applications)
Sensing Cable Input: Compatible with all SeaHawk sensing cables, as well as SD-Z and SD-Z1 spot detectors
Requires Sensor: Sensing cable, SD-Z, or SD-Z1
One Cable Input: Sensing cable and SD-Z require 15ft (4.57m) leader cable and EOL (included). SD-Z1 connects directly to transmitter.
Maximum Length: 50ft (15.24m)
Transmission
Interval: 10-17 seconds (random)
Frequency: 418 MHz
Range: Up to 100 ft. (30.5m)
Operating Temperature: 32°F to 122°F (0°C to 50°C)
Storage Temperature: -4°F to 158°F (-20°C to °C)
Dimensions:
Wireless Transmitter: 2.375″ W X 1.875″ H X 1.0″ D (60.3mm W x 47.6mm H x 25.4mm D)
Weight: 5.0 oz. (141.7g)
Mounting: Wall mount or free-standing
Certification: FCC Part 15, Class B; FCC ID: M5ZWOWANA
Related Products
Key Features
Accommodates:
up to 300 feet (91 meters) of conductive fluid sensing cable and/or spot detectors, or
up to 210 feet (64 meters) of chemical sensing cable
Visible alarm indicator
Two Form C output relays for leak and fault alarms
Audible and visible alarm notification
Adjustable leak alarm sensitivity thresholds
Configurable for supervised or non-supervised operation
Distinguishes normal conditions from alarm conditions
Quickly returns to normal
Included Equipment: LD310 controller, leader cable, end-of-line (EOL) terminator
Additional Requirements: Power supply WA-DC-5-ST, sensing cable and spot detector (as needed for application)
Power: Requires an isolated power supply.
5VDC Isolated (±10%) @ 100mA max; requires RLE power supply WA-DC-5-ST (not included)
Inputs
Leak Detection Cable: Compatible with all SeaHawk sensing cables as well as SD-Z and SD-Z1 spot detectors (not included)
One Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)
Maximum Sensing Cable Length: 300ft (91m) of conductive fluid sensing cable, or 210ft (64m) of chemical sensing cable
Detection Response Time: When used with conductive fluid or chemical sensing cables, less than 20sec; 10sec typical.
Outputs: 2 Form C Alarm Relays (leak and fault); 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable as supervised or non-supervised
Alarm Notification
Audible Alarm: 85dB @ 10cm (min)
Visual Alarm: Bi-color LED
Front Panel Interface
Audible Alarm: Indicates cable break or leak detected
LED Indicator:
Normal Operation: Green
Cable Fault: Flashing orange
Leak Detected: Flashing red
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 2.7″W x 4.4″H x 1.38″D (69mmW x 112mmH x 35mmD)
Weight: 3.0 oz. (85.0g)
Mounting: Surface mount
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010-1; RoHS compliant
Key Features
Monitors:
up to 1,000 feet (305 meters) of conductive fluid sensing cable and/or spot detectors, or
up to 700 feet (213 meters) of chemical sensing cable
Three LED indicators: Power, Leak, Fault
Selectable audible alarm annunciation
Configurable for supervised or non-supervised operation
Adjustable sensitivity settings
Wall mount enclosure
Two Form C output relays for leak and fault alarms
Included Equipment: LD1000 controller, leader cable, end-of-line (EOL) terminator
Additional Requirements: RLE power supply, sensing cable and spot detector (as needed for application)
Power: Requires an isolated power supply for DC operation.
24VDC (±10%) Isolated @ 300mA max.; requires RLE power supply PSWA-DC-24-ST (not included)
24VAC (±10%) @ 300mA max.; requires RLE power supply WA-AC-24-ST (not included)
Inputs
Leak Detection Cable: Compatible with SeaHawk sensing cables (not included)
Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)
Maximum Sensing Cable Length: 1,000 feet (305m) of conductive fluid sensing cable, or 700 feet (213m) of chemical sensing cable or hydrocarbon sensing cable
Detection Response Time: Configurable for 10sec or 2min, ±10%, when used with conductive fluid or chemical sensing cables.
Outputs: 1 Form C Leak Relay, 1 Form C Cable Fault Relay, configurable to 2 Summary Alarm Relays; 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for supervised or non-supervised, latched or non-latched
Alarm Notification: Audible Alarm 85DBA @ 2ft (0.6m); Selectable
Front Panel Interface
LED Indicators: Power: 1 green (on/off); Cable Fault: 1 amber; Leak Detected: 1 red
Push Buttons: 1: Quiet,Reset, Test
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 4.125″W x 5.5″H x 2.25″D (105mmW x 140mmH x 58mmD)
Weight: 27.0 oz. (765g)
Mounting: Wall mount
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant
Key Features
No exposed metal sensing posts – nothing to rust or corrode
Potted electronics
Functions when submerged in water
Adjustable probes are easily adjusted to desired height
Can be screwed or ram set to floor or baseboard
Small footprint/enclosure
Simple installation
Ideal for tight areas
Power: Requires an isolated power supply.
24VDC (±10%) Isolated @ 0.1A max.; requires RLE power supply PSWA-DC-24-ST (not included)
If a DC power supply is used the SD-RO1 will be a latching device – once an alarm is detected, the spot detector will remain in an alarm state until power is cycled to the SD-RO1.
24VAC (±10%) Isolated @ 0.1A max.; requires RLE power supply WA-AC-24-ST (not included)
Relay Output: Dry Contact, Form C; 1A @ 24VDC, 0.5A resistive @ 120VAC
Leader Cable (Non-sensing)
Length: 14 feet (4.27m)
Connector: N/A
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)
Weight: 7 oz. (192g)
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant
Key Features
No exposed metal sensing posts – nothing to rust or corrode
Potted electronics
Functions when submerged in water
Adjustable probes are easily adjusted to desired height
Can be screwed or ram set to floor or baseboard
Small footprint/enclosure
Simple installation
Ideal for tight areas
Power: The SD is usually powered by the RLE FMS or RA1x2. In the event that it is not used in conjunction with one of these products, it does require an isolated power supply.
24VDC (±10%) Isolated @ 0.1A max.; requires RLE power supply PSWA-DC-24-ST (not included)
If a DC power supply is used the SD will be a latching device – once an alarm is detected, the spot detector will remain in an alarm state until power is cycled to the SD.
4VAC (±10%) Isolated @ 0.1A max.; requires RLE power supply WA-DAC-24-ST (not included)
Solid State Output: 12-36VAC @ 0.01A min., 0.1A max.; 18-36VDC @ 0.01A min., 0.1A max.
Leader Cable (Non-sensing)
Length: 14 feet (4.27m)
Connector: N/A
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)
Weight: 4 oz. (105g)
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant.
Key Features
No exposed metal sensing posts – nothing to rust or corrode
Potted electronics
Functions when submerged in water
Adjustable probes are easily adjusted to desired height
Can be screwed or ram set to floor or baseboard
Small footprint/enclosure
Simple installation
Ideal for tight areas
Power: N/A (powered by panel)
Leader Cable (Non-sensing)
Length: 14 feet (4.27m)
Connector: N/A
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)
Weight: 5 oz. (136g)
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant
Key Features
Plug-and-Play configuration enables quick and effective monitoring of any local or remote facility
Web-accessible with a clean, easy to use, mobile-friendly web interface
Monitors eight dry contact inputs and four temperature or temperature/humidity sensors, plus one zone of leak detection
Single zone leak detection supports up to 200’ of leak detection sensing cable and/or spot detectors
USB power – run the F200 from a wall outlet via included adapter or a USB port on a server or other computer
Real-time monitoring, advanced notifications, and customizable thresholds
Multiple alarm notification configurations including audible and visible indicators, integrated web interface, email messaging, and SNMP traps
Relay output allows for simple control of an external device upon alarm condition
Modbus output enables simple integration to a Building Management System (BMS)
Integrated logging and trending, including CSV downloadable trending data.
Included Equipment: F200 controller, network cable, USB cable – USB mini B to USB A, 5V USB wall wart with Type A, C, G, and I blades
Additional Requirements: Digital temperature sensors, digital temperature/humidity sensors, leak detection leader cable, leak detection sensing cable, end-of-line terminator, rack mount kit (as needed for application)
Power: (US) 5VDC @ 500mA max; 110/240VAC 50/60Hz; wall adapter (Type A blade) to USB connector, with Type C, G, and I blades for international use (included)
Wired Inputs
Temperature/Humidity: 4 digital temperature or digital temperature/humidity sensor inputs; RJ11 connectors; plug-and-play; configurable alarm points
Digital (Dry Contact): 8 digital alarm points; configurable
Sensing Cable: One zone leak detection, compatible with all SeaHawk sensing cables and SD-Z and SD-Z1 spot detectors
Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (not included), or wire one SD-Z1 directly to the F200
Maximum Sensing Cable Length: 200ft (61m) of conductive fluid sensing cable, or 140ft (43m) of chemical sensing cable
Relay Output: 1 Form C summary relay; 2A @ 30VDC, 0.5A @ 125VAC. Configurable as summary alarm or manual operation.
Alarm Notification
Panel: Audible alarm, visible LED
Integrated Web Interface: Dashboard overview with alarm indicators
Email: 8 email recipients; email sent on alarm to recipients, distribution list, or email-to-SMS
SNMP Traps: Multiple community strings
Relay: 1 Form C summary relay output
Web Interface Login Security: 8 passwords read only; 8 passwords read/write
Communication Port
Ethernet: 10/100 BaseT, RJ45 connector; 500 VAC RMS isolation; DHCP enabled; Static IP-addressable
Protocols
TCP/IP: ARP; DNS; UDP; DHCP; ICMP
HTML: Supports multiple simultaneous connections
SMTP (email): SMTP authentication; SMTP relay; supports SSL; up to 8 recipients
Modbus TCP/IP: Modbus slave; TCP/IP transmission protocol
SNMP: V1; V2C MIB-2 compliant; NMS Manageable with Get and Traps: V2C Get, V2C and V1 Traps
NTP: Custom server settings
Logging: Logs 50 most recent alarm and return to normal events with date/time stamp
Trending: Records up to 86,400 points of sensor data. Sample interval set from 1 second to 1 day. CSV downloadable.
Operating Environment
Temperature: -40° to 185°F (-40° to 85°C)
Humidity: 0% to 100% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -40° to 185°F (-40° to 85°C)
Dimensions: 5.63″W x 1.0″H x 2.63″D (143mmW x 25mmH x 67mmD)
Weight: 10.1 oz. (287g)
Mounting: Stand alone; keyholes included for wall mount; rack mount bracket available
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010-1; certified to CSA C22.2 NO. 61010-1; RoHS compliant
Designed to work with all of RLE’s leak detection controllers, the SD-Z spot detector can be connected to other SD-Z units or to sensing or non-sensing cable.
Key Features
No exposed metal sensing posts – nothing to rust or corrode
Potted electronics
Functions when submerged in water
Adjustable probes are easily adjusted to desired height
Can be screwed or ram set to floor or baseboard
Small footprint/enclosure
Simple installation
Ideal for tight areas
Power: N/A (powered by panel)
Leader Cable (Non-sensing)
Length: 10 inches (0.25m); male & female connector
Connector: 1 male, 1 female; 4 pin, 0.96in (24.4mm) diameter; connects to SeaHawk sensing cable (SC) cable or non-sensing cable (NSC)
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)
Weight: 3 oz. (93g)
Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant