Navigation
Account
Sign in / Register
+ (246) 271-2059 | [email protected]
  • Sidebar
  • Showing all 8 results

  • Spot Detector (SD-RO1)

    Key Features

    No exposed metal sensing posts – nothing to rust or corrode

    Potted electronics

    Functions when submerged in water

    Adjustable probes are easily adjusted to desired height

    Can be screwed or ram set to floor or baseboard

    Small footprint/enclosure

    Simple installation

    Ideal for tight areas

    Power: Requires an isolated power supply.

    24VDC (±10%) Isolated @ 0.1A max.; requires RLE power supply PSWA-DC-24-ST (not included)

    If a DC power supply is used the SD-RO1 will be a latching device – once an alarm is detected, the spot detector will remain in an alarm state until power is cycled to the SD-RO1.

    24VAC (±10%) Isolated @ 0.1A max.; requires RLE power supply WA-AC-24-ST (not included)

    Relay Output: Dry Contact, Form C; 1A @ 24VDC, 0.5A resistive @ 120VAC

    Leader Cable (Non-sensing)

    Length: 14 feet (4.27m)

    Connector: N/A

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)

    Weight: 7 oz. (192g)

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant

  • Spot Detector (SD-Z1)

    Key Features

    No exposed metal sensing posts – nothing to rust or corrode

    Potted electronics

    Functions when submerged in water

    Adjustable probes are easily adjusted to desired height

    Can be screwed or ram set to floor or baseboard

    Small footprint/enclosure

    Simple installation

    Ideal for tight areas

    Power: N/A (powered by panel)

    Leader Cable (Non-sensing)

    Length: 14 feet (4.27m)

    Connector: N/A

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)

    Weight: 5 oz. (136g)

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant

  • Spot Detector (SD)

    Key Features

    No exposed metal sensing posts – nothing to rust or corrode

    Potted electronics

    Functions when submerged in water

    Adjustable probes are easily adjusted to desired height

    Can be screwed or ram set to floor or baseboard

    Small footprint/enclosure

    Simple installation

    Ideal for tight areas

    Power: The SD is usually powered by the RLE FMS or RA1x2. In the event that it is not used in conjunction with one of these products, it does require an isolated power supply.

    24VDC (±10%) Isolated @ 0.1A max.; requires RLE power supply PSWA-DC-24-ST (not included)

    If a DC power supply is used the SD will be a latching device – once an alarm is detected, the spot detector will remain in an alarm state until power is cycled to the SD.

    4VAC (±10%) Isolated @ 0.1A max.; requires RLE power supply WA-DAC-24-ST (not included)

    Solid State Output: 12-36VAC @ 0.01A min., 0.1A max.; 18-36VDC @ 0.01A min., 0.1A max.

    Leader Cable (Non-sensing)

    Length: 14 feet (4.27m)

    Connector: N/A

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)

    Weight: 4 oz. (105g)

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant.

  • Spot Detectors

    Designed to work with all of RLE’s leak detection controllers, the SD-Z spot detector can be connected to other SD-Z units or to sensing or non-sensing cable.

    Key Features

    No exposed metal sensing posts – nothing to rust or corrode

    Potted electronics

    Functions when submerged in water

    Adjustable probes are easily adjusted to desired height

    Can be screwed or ram set to floor or baseboard

    Small footprint/enclosure

    Simple installation

    Ideal for tight areas

    Power: N/A (powered by panel)

    Leader Cable (Non-sensing)

    Length: 10 inches (0.25m); male & female connector

    Connector: 1 male, 1 female; 4 pin, 0.96in (24.4mm) diameter; connects to SeaHawk sensing cable (SC) cable or non-sensing cable (NSC)

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 1.55″W x 2.0″H x 1.0″D (39.4mmW x 50.8mmH x 25.4mmD)

    Weight: 3 oz. (93g)

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant

  • Zone Controllers (F200)

    Key Features

    Plug-and-Play configuration enables quick and effective monitoring of any local or remote facility

    Web-accessible with a clean, easy to use, mobile-friendly web interface

    Monitors eight dry contact inputs and four temperature or temperature/humidity sensors, plus one zone of leak detection

    Single zone leak detection supports up to 200’ of leak detection sensing cable and/or spot detectors

    USB power – run the F200 from a wall outlet via included adapter or a USB port on a server or other computer

    Real-time monitoring, advanced notifications, and customizable thresholds

    Multiple alarm notification configurations including audible and visible indicators, integrated web interface, email messaging, and SNMP traps

    Relay output allows for simple control of an external device upon alarm condition

    Modbus output enables simple integration to a Building Management System (BMS)

    Integrated logging and trending, including CSV downloadable trending data.

    Included Equipment: F200 controller, network cable, USB cable – USB mini B to USB A, 5V USB wall wart with Type A, C, G, and I blades

    Additional Requirements: Digital temperature sensors, digital temperature/humidity sensors, leak detection leader cable, leak detection sensing cable, end-of-line terminator, rack mount kit (as needed for application)

    Power: (US) 5VDC @ 500mA max; 110/240VAC 50/60Hz; wall adapter (Type A blade) to USB connector, with Type C, G, and I blades for international use (included)

    Wired Inputs

    Temperature/Humidity: 4 digital temperature or digital temperature/humidity sensor inputs; RJ11 connectors; plug-and-play; configurable alarm points

    Digital (Dry Contact): 8 digital alarm points; configurable

    Sensing Cable: One zone leak detection, compatible with all SeaHawk sensing cables and SD-Z and SD-Z1 spot detectors

    Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (not included), or wire one SD-Z1 directly to the F200

    Maximum Sensing Cable Length: 200ft (61m) of conductive fluid sensing cable, or 140ft (43m) of chemical sensing cable

    Relay Output: 1 Form C summary relay; 2A @ 30VDC, 0.5A @ 125VAC. Configurable as summary alarm or manual operation.

    Alarm Notification

    Panel: Audible alarm, visible LED

    Integrated Web Interface: Dashboard overview with alarm indicators

    Email: 8 email recipients; email sent on alarm to recipients, distribution list, or email-to-SMS

    SNMP Traps: Multiple community strings

    Relay: 1 Form C summary relay output

    Web Interface Login Security: 8 passwords read only; 8 passwords read/write

    Communication Port

    Ethernet: 10/100 BaseT, RJ45 connector; 500 VAC RMS isolation; DHCP enabled; Static IP-addressable

    Protocols

    TCP/IP: ARP; DNS; UDP; DHCP; ICMP

    HTML: Supports multiple simultaneous connections

    SMTP (email): SMTP authentication; SMTP relay; supports SSL; up to 8 recipients

    Modbus TCP/IP: Modbus slave; TCP/IP transmission protocol

    SNMP: V1; V2C MIB-2 compliant; NMS Manageable with Get and Traps: V2C Get, V2C and V1 Traps

    NTP: Custom server settings

    Logging: Logs 50 most recent alarm and return to normal events with date/time stamp

    Trending: Records up to 86,400 points of sensor data. Sample interval set from 1 second to 1 day. CSV downloadable.

    Operating Environment

    Temperature: -40° to 185°F (-40° to 85°C)

    Humidity: 0% to 100% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -40° to 185°F (-40° to 85°C)

    Dimensions: 5.63″W x 1.0″H x 2.63″D (143mmW x 25mmH x 67mmD)

    Weight: 10.1 oz. (287g)

    Mounting: Stand alone; keyholes included for wall mount; rack mount bracket available

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010-1; certified to CSA C22.2 NO. 61010-1; RoHS compliant

  • Zone Controllers (LD1000)

    Key Features

    Monitors:

    up to 1,000 feet (305 meters) of conductive fluid sensing cable and/or spot detectors, or

    up to 700 feet (213 meters) of chemical sensing cable

    Three LED indicators: Power, Leak, Fault

    Selectable audible alarm annunciation

    Configurable for supervised or non-supervised operation

    Adjustable sensitivity settings

    Wall mount enclosure

    Two Form C output relays for leak and fault alarms

    Included Equipment: LD1000 controller, leader cable, end-of-line (EOL) terminator

    Additional Requirements: RLE power supply, sensing cable and spot detector (as needed for application)

    Power: Requires an isolated power supply for DC operation.

    24VDC (±10%) Isolated @ 300mA max.; requires RLE power supply PSWA-DC-24-ST (not included)

    24VAC (±10%) @ 300mA max.; requires RLE power supply WA-AC-24-ST (not included)

    Inputs

    Leak Detection Cable: Compatible with SeaHawk sensing cables (not included)

    Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)

    Maximum Sensing Cable Length: 1,000 feet (305m) of conductive fluid sensing cable, or 700 feet (213m) of chemical sensing cable or hydrocarbon sensing cable

    Detection Response Time: Configurable for 10sec or 2min, ±10%, when used with conductive fluid or chemical sensing cables.

    Outputs: 1 Form C Leak Relay, 1 Form C Cable Fault Relay, configurable to 2 Summary Alarm Relays; 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for supervised or non-supervised, latched or non-latched

    Alarm Notification: Audible Alarm 85DBA @ 2ft (0.6m); Selectable

    Front Panel Interface

    LED Indicators: Power: 1 green (on/off); Cable Fault: 1 amber; Leak Detected: 1 red

    Push Buttons: 1: Quiet,Reset, Test

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 4.125″W x 5.5″H x 2.25″D (105mmW x 140mmH x 58mmD)

    Weight: 27.0 oz. (765g)

    Mounting: Wall mount

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010, CSA C22.2 No. 61010-1, IEC 61326:1997; RoHS compliant

  • Zone Controllers (LD310)

    Key Features

    Accommodates:

    up to 300 feet (91 meters) of conductive fluid sensing cable and/or spot detectors, or

    up to 210 feet (64 meters) of chemical sensing cable

    Visible alarm indicator

    Two Form C output relays for leak and fault alarms

    Audible and visible alarm notification

    Adjustable leak alarm sensitivity thresholds

    Configurable for supervised or non-supervised operation

    Distinguishes normal conditions from alarm conditions

    Quickly returns to normal

    Included Equipment: LD310 controller, leader cable, end-of-line (EOL) terminator

    Additional Requirements: Power supply WA-DC-5-ST, sensing cable and spot detector (as needed for application)

    Power: Requires an isolated power supply.

    5VDC Isolated (±10%) @ 100mA max; requires RLE power supply WA-DC-5-ST (not included)

    Inputs

    Leak Detection Cable: Compatible with all SeaHawk sensing cables as well as SD-Z and SD-Z1 spot detectors (not included)

    One Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)

    Maximum Sensing Cable Length: 300ft (91m) of conductive fluid sensing cable, or 210ft (64m) of chemical sensing cable

    Detection Response Time: When used with conductive fluid or chemical sensing cables, less than 20sec; 10sec typical.

    Outputs: 2 Form C Alarm Relays (leak and fault); 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable as supervised or non-supervised

    Alarm Notification

    Audible Alarm: 85dB @ 10cm (min)

    Visual Alarm: Bi-color LED

    Front Panel Interface

    Audible Alarm: Indicates cable break or leak detected

    LED Indicator:

    Normal Operation: Green

    Cable Fault: Flashing orange

    Leak Detected: Flashing red

    Operating Environment

    Temperature: 32° to 122°F (0° to 50°C)

    Humidity: 5% to 95% RH, non-condensing

    Altitude: 15,000ft (4,572m) max.

    Storage Environment: -4° to 158°F (-20° to 70°C)

    Dimensions: 2.7″W x 4.4″H x 1.38″D (69mmW x 112mmH x 35mmD)

    Weight: 3.0 oz. (85.0g)

    Mounting: Surface mount

    Certifications: CE; ETL listed: conforms to UL 61010-1, EN 61010-1; RoHS compliant

  • Zone Controllers (Wi-LD)

    Key Features

    Wireless with compact ABS enclosure

    Couples with up to 50 feet (15.24m) of leak detection sensing cable or a spot detector

    Transmission range of up to 100 feet (30.5m)

    3.6V lithium AA battery life up to two years

    Electronics feature a condensation-resistant coating

    Reliable communication

    FCC certified transmitter

    Pairs with conductive fluid sensing cable, chemical sensing cable, an SD-Z or an SD-Z1 for single zone leak detection

    Easy installation and simple to relocate

    Power: 3.6V Battery Lithium AA; included

    Lithium AA Battery Life: Up to 2 years

    Included Accessories: Leader cable and end-of-line terminator (EOL)

    Additional Equipment Required for Operation

    Wi-MGR

    Conductive fluid sensing cable, chemical sensing cable, an SD-Z or an SD-Z1

    Leader cable and end-of-line terminator (included – required only for SD-Z and sensing cable applications)

    Sensing Cable Input: Compatible with all SeaHawk sensing cables, as well as SD-Z and SD-Z1 spot detectors

    Requires Sensor: Sensing cable, SD-Z, or SD-Z1

    One Cable Input: Sensing cable and SD-Z require 15ft (4.57m) leader cable and EOL (included). SD-Z1 connects directly to transmitter.

    Maximum Length: 50ft (15.24m)

    Transmission

    Interval: 10-17 seconds (random)

    Frequency: 418 MHz

    Range: Up to 100 ft. (30.5m)

    Operating Temperature: 32°F to 122°F (0°C to 50°C)

    Storage Temperature: -4°F to 158°F (-20°C to °C)

    Dimensions:

    Wireless Transmitter: 2.375″ W X 1.875″ H X 1.0″ D (60.3mm W x 47.6mm H x 25.4mm D)

    Weight: 5.0 oz. (141.7g)

    Mounting: Wall mount or free-standing

    Certification: FCC Part 15, Class B; FCC ID: M5ZWOWANA